About the Author(s)


Sheryl Mohabir Email symbol
Division of Radiodiagnosis, Department of Medical Imaging and Clinical Oncology, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa

Richard D. Pitcher symbol
Division of Radiodiagnosis, Department of Medical Imaging and Clinical Oncology, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa

Rubeshan Perumal symbol
Centre for the AIDS Programme of Research in South Africa, University of KwaZulu-Natal, Durban, South Africa

Matthew D.M. Goodier symbol
Department of Radiology, Grey’s Hospital Pietermaritzburg, University of KwaZulu-Natal, KwaZulu-Natal, South Africa

Citation


Mohabir S, Pitcher RD, Perumal R, Goodier MDM. The efficacy of pineapple juice as a negative oral contrast agent in magnetic resonance cholangiopancreatography. S Afr J Rad. 2020;24(1), a1875. https://doi.org/10.4102/sajr.v24i1.1875

Original Research

The efficacy of pineapple juice as a negative oral contrast agent in magnetic resonance cholangiopancreatography

Sheryl Mohabir, Richard D. Pitcher, Rubeshan Perumal, Matthew D.M. Goodier

Received: 26 Feb. 2020; Accepted: 13 May 2020; Published: 29 July 2020

Copyright: © 2020. The Author(s). Licensee: AOSIS.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Background: During magnetic resonance cholangiopancreatography (MRCP), the pancreatobiliary ducts can be obscured by the high-intensity signal from the stomach and duodenum. Pineapple juice may be an alternative to commercially available negative contrast agents, but has not been evaluated locally.

Objectives: To evaluate the efficacy of a local, off-the-shelf pineapple juice preparation as a negative oral contrast agent for MRCP.

Method: An observational, analytical study was conducted during January–December 2017. A 1.5 Tesla MRCP sequence was performed immediately before and after ingestion of 250 mL of a local, commercially-available pineapple juice preparation. Image evaluation was performed by two radiologists with independent, blind assessment of gastric/duodenal signal intensity and biliary /pancreatic duct visibility, before and after pineapple juice.

Results: Fifty adult patients (F = 44, 88%) with median age 44 years (IQR: 34.75, 57) were included. After pineapple juice administration, there was significant measured (1661.51 vs. 1409.94, p < 0.01) and perceived (2.16 vs. 2.72, p < 0.01) duodenal signal reduction but no significant change in measured (1081.17 vs. 1044.38, p = 0.34) or perceived (2.73 vs. 2.84, p = 0.14) gastric signal intensity. Visibility of the common bile duct was significantly improved (3.67 vs. 3.86, p < 0.01), whilst that of the main pancreatic duct showed no significant change (2.92 vs. 2.86, p = 0.44).

Conclusion: The local pineapple juice preparation used in this study is an effective, affordable and natural negative oral contrast agent for enhancement of MRCP images, and specifically improves visualisation of the common bile duct.

Keywords: MRCP; pineapple juice; negative oral contrast; pancreatobiliary ducts; common bile duct; pancreatic duct.

Introduction

Magnetic resonance cholangiopancreatography (MRCP) is a non-invasive technique for imaging the biliary and pancreatic ducts.1 Although endoscopic retrograde cholangiopancreatography (ERCP) has enhanced the evaluation of these ducts over the past 50 years and has both diagnostic and therapeutic capacity,2 it is invasive, utilises ionising radiation, has relatively high morbidity and requires special preparation, as well as sedation.3,4 Despite endoscopic ultrasound (EUS) achieving 88% – 97% sensitivity and 96% – 100% specificity for choledocholithiasis, its role in this domain is not well established.5 As MRCP has diagnostic accuracy comparable to ERCP, it is preferred for initial pancreaticobiliary investigation, with ERCP reserved for therapeutic interventions and biopsy.6,7,8,9,10,11,12

Magnetic resonance cholangiopancreatography utilises heavily T2-weighted, mainly coronal, maximum intensity projections (MIP), similar to conventional cholangiopancreatography.13 However, the high-intensity signal from adjacent gastric and duodenal fluids may obscure the bile and pancreatic ducts, limiting diagnostic accuracy.14,15 To overcome this, patients are fasted before the examination and a negative oral contrast agent may be administered to further suppress signal from these structures.16 Negative contrast agents use the paramagnetic properties of heavy metal ions, particularly manganese, barium and gadolinium, to reduce T1 and T2 relaxation times, thereby increasing T1- and decreasing T2-signal intensity.17,18 Commercially available agents have been shown to significantly improve visualisation of the bile and pancreatic ducts, with no impact on duct dimensions.19 A systematic review of oral negative contrast agents for improving visualisation of the hepatobiliary system during MRCP, which included 25 studies over 25 years from 1990 to 2015, revealed that the application of an oral substance for gastrointestinal signal suppression was effective in 23 out of the 25 studies.20 However, these are expensive, not widely available and generally unpalatable, restricting their use, especially in resource-limited settings.

The ideal oral contrast agent should be affordable, palatable and evenly distributed in the gastrointestinal tract; it should not be toxic, diluted during transit or stimulate peristalsis.21 There is an ongoing quest for a cheaper, more palatable, but effective, natural alternative to commercially available negative MRCP contrast agents.

Pineapple is the fruit with the highest manganese concentration.22 Five prior studies from Europe (n = 4) and South America (n = 1) with cohorts between 10 and 100 subjects have assessed commercially available pineapple juice as a negative MRCP contrast agent.22,23,24,25,26 Three studies used volumes more than 400 mL, whilst two studies used 180 mL, in combination with commercially available gadolinium contrast. Pineapple juice with manganese concentrations greater than 15 mg/L was found to be comparable to the commercially available negative contrast agent ferumoxsil.23

Pineapple juice is routinely used as a negative oral MRCP contrast agent at Grey’s Hospital, a 530-bed public-sector tertiary-level teaching hospital in Pietermaritzburg, Kwazulu-Natal, South Africa. However, the efficacy of the institutional MRCP protocol has not been formally evaluated. The aim of this study was, therefore, to assess the role of an off-the-shelf, conveniently packaged (carton with attached straw), easily consumable quantity (250 mL) of pineapple juice as a negative oral contrast agent for MRCP within a resource-constrained specialist diagnostic radiology service.

Methods

An observational, comparative, analytical study was conducted within the radiology department at Grey’s Hospital in KwaZulu-Natal, South Africa. The study population included all adult patients (18 years and older) undergoing MRCP with pineapple juice as a negative contrast agent, from 01 January to 31 December 2017. Patients with a history of a previous gastrectomy were excluded.

Information relating to patients’ age, gender and indication for MRCP were recorded. All patients fasted for a minimum of 10 h before the procedure. Standard MRCP sequences before and immediately after oral administration of 250 mL of pineapple juice (Liqui Fruit Summer Pine, Ceres, South Africa) were completed on all patients, utilising a 1.5 Tesla MR Unit (Philips Intera System, Amsterdam, Netherlands) with a SENSE body coil. The pre- and post-contrast images (examples provided in Figures 1 and 2) were re-labelled by a randomisation table to facilitate a blinded review.

FIGURE 1: This maximum intensity projection coronal reconstruction magnetic resonance cholangiopancreatography image demonstrates a significant reduction in signal intensity of the stomach from moderate to slight signal intensity (Δ maximum ROI from 1883.5 to 1020): (a) pre-contrast magnetic resonance cholangiopancreatography; (b) post-contrast magnetic resonance cholangiopancreatography. Correspondingly, visualisation of the common bile duct (CBD) improved from good to excellent. This is explained by reduction in signal in the gastric antrum resulting in improved visualisation of the overlapping CBD. The duodenum had no subjective improvement with moderate signal intensity in both pre- and post-contrast imaging (Δ maximum ROI 2145 → 1897). The main pancreatic duct (MPD) remained visible with some difficulty.

FIGURE 2: This maximum intensity projection coronal reconstruction magnetic resonance cholangiopancreatography image demonstrates a significant reduction in the signal intensity of the duodenum from high to moderate signal intensity (Δ maximum ROI 2230 → 2192): (a) pre-contrast magnetic resonance cholangiopancreatography; (b) post-contrast magnetic resonance cholangiopancreatography. Correspondingly, visualisation of the common bile duct (CBD) improved from fair to excellent, and visualisation of the main pancreatic duct (MPD) improved from good to excellent.

Images were assessed by two radiologists: a consultant with more than five years’ experience and a senior radiology trainee. Signal intensity (SI) of the stomach and duodenum was measured on pre- and post-contrast images, using the Carestream picture archiving and communication system (PACS). A 100 mm2 region of interest (ROI) was used to assess maximum gastric SI on MIP, whilst a smaller, oval ROI was used for the duodenum. The overall perceived SI of the stomach and duodenum were recorded using a 4-point Likert scale (Table 1). The visibility of the common bile duct (CBD) and main pancreatic duct (MPD) before and after pineapple juice administration were graded qualitatively using the 4-point Likert method (Table 2).

TABLE 1: Perception of signal intensity in the stomach and duodenum.
TABLE 2: Visibility and detectability of common bile duct or main pancreatic duct.

All data were analysed using R 3.5.3. For all statistical comparisons, a 5% level of significance was used. All data were assessed for normality, and non-parametric tests were used where necessary. Inter-rater agreement and reliability were assessed using Kendall’s coefficient of concordance and the intraclass correlation coefficient. A mixed-model two-way analysis of variance (ANOVA) was used to compare the measured and perceived difference in SI before and after pineapple juice ingestion, and to identify the changes in the visualisation of the CBD and MPD.

Ethical consideration

This study was approved by the Biomedical Research Ethics Committee of the University of KwaZulu-Natal (BE622/16) and the Kwazulu-Natal Provincial Health Research and Ethics Committee (KZ_2016RP43_873). Informed consent was obtained from all patients involved in this study.

Results

A total of 50 patients were included in the study; the median age was 44 years (IQR 43.75, 57), and the majority (88%) were women. The most common indication for MRCP was suspected choledocholithiasis or benign biliary strictures (72%), whilst post-surgical evaluation (20%) was the next most common indication.

After pineapple juice administration, there was significant measured (1661.51 vs. 1409.94, p < 0.01) and perceived (2.16 vs. 2.72, p < 0.01) duodenal signal reduction but no significant change in measured (1081.17 vs. 1044.38, p = 0.34) or perceived (2.73 vs. 2.84, p = 0.14) gastric SI (Table 3). Visibility of the CBD was significantly improved (3.67 vs. 3.86, p < 0.01), whilst that of the MPD showed no significant change (2.92 vs. 2.86, p = 0.44).

TABLE 3: Effect of pineapple juice as a negative contrast agent in the evaluation of pancreatobiliary structures by magnetic resonance cholangiopancreatography.

There was substantial agreement between reviewers on all study items: measured SI from the stomach (κ = 0.97, 95% confidence interval [CI] 0.96–0.98) and the duodenum (κ = 0.88, 95% CI 0.83–0.92); perceived SI from the stomach (κ = 0.81, 95% CI 0.73–0.87) and the duodenum (κ = 0.9, 95% CI 0.86–0.93); subjective assessments of the visibility of the CBD (κ = 0.88, 95% CI 0.83–0.92) and MPD (κ = 0.91, 95% CI 0.86–0.94).

Discussion

To our knowledge, this is one of the few studies to date that quantitatively evaluates changes in MRCP SI after pineapple juice administration.22,23,24,25,26 Our finding that 250 mL of an affordable, local, off-the-shelf pineapple juice preparation decreased duodenal SI by 15% and significantly enhanced CBD visualisation points to its efficacy as an MRCP negative oral contrast agent in our setting. This has general applicability in South Africa and more broadly in Africa, where pineapple juice is readily available and affordable. Our findings thus have the potential to influence MRCP protocols on our continent.

The only prior study that quantified SI changes following pineapple juice administration was confounded by the off-label co-administration of 1 mL of oral gadolinium, a potent synthetic negative contrast agent.24 This study achieved 96% and 90% quantitative loss of gastric and duodenal fluid SI, respectively, and a mean qualitative improvement of 2 points on a 4-point Likert scale, similar to that used in our study. However, the safety, efficacy and feasibility of oral gadolinium have yet to be definitively assessed.24,27 Although the degree of duodenal signal suppression was substantially lower than the aforementioned study, the use of pineapple juice in this study resulted in 86% (vs. 76% without pineapple juice) of our images displaying excellent visualisation of the CBD.

The volume of pineapple juice administered in this study was that of a commercially packaged juice carton with an attached straw (250 mL) which was convenient for consumption in the supine position. Most in vivo studies to date have administered 400 mL of pineapple juice, although the exact amount of manganese has not been disclosed.22,23 Electrothermal atomic absorption spectrometry assay demonstrated a manganese concentration of 27.6 mg/L for pure pineapple juice.22 The concentration of manganese in commercially available pineapple juice preparations ranges from 9.3 mg/L to 12.7 mg/L, which, although substantially lower than the 40 mg/L manganese concentration achieved with commercially prepared manganese contrast agents, was shown to be effective for elimination of signal from the digestive tract.19,26 Studies of blueberry juice as a negative MRCP contrast agent report effective manganese concentrations of 19 mg/L28 and 30 mg/L29, which is only achieved with volumes of 430 mL and 600 mL of most commercially available blueberry juices, respectively. In addition, 100 mL of date syrup can be used as an effective negative contrast agent at MRCP, with adequate suppression of signal from the gastrointestinal system, improved visualisation of the biliary system and increased calibre of the pancreatic duct because of the acidic nature of date syrup.30

The ideal dose of pineapple juice may similarly be dependent on the concentration of manganese and the propensity of the dose to accumulate in the stomach and duodenum whilst displacing gastrointestinal fluids. The lower volume of pineapple juice administered in our study, in comparison to the volume administered in most other studies, may account for poor signal suppression in the stomach resulting from the rapid passage of contrast into the duodenum, despite the timing of MRCP immediately after pineapple juice administration. Our failure to achieve an improvement of pancreatic duct visualisation is likely because of the anatomical overlapping of the MPD by the stomach on conventional coronal maximal intensity projection reconstruction.13,15 There were no serious adverse events in this study, in keeping with prior studies that demonstrated that manganese from orally administered fruit juices are poorly absorbed and do not significantly elevate serum concentrations.29

Our failure to demonstrate significant suppression of gastric SI or improvement of pancreatic duct visualisation highlights the need for further refinement of our MRCP protocol, including optimisation of the dose and timing of pineapple juice administration. Nonetheless, our study provides a useful baseline for further work in this domain. It is expected that other centres in South Africa and Africa will be prompted to adopt a similar, affordable protocol. The ideal volume of pineapple juice has still to be defined and is likely dependent on the concentration of manganese in each preparation. Further work could thus involve spectrometric evaluation of manganese concentrations in locally available pineapple juice preparations. In clinical practice it may be useful to administer a minimum of 250 mL and up to the maximum tolerated volume of pineapple juice, given the relatively low cost of the product.

Conclusion

This study demonstrated that a store-bought, conveniently packaged and easily consumable quantity of pineapple juice improves the quality of MRCP imaging, and specifically improves visualisation of the CBD.

Acknowledgements

The authors thank the Department of Radiology at Grey’s Hospital for assisting them with performing the study (i.e., informed consent, randomising and blinding images).

Competing interests

The authors declare that they have no potential conflicts of interest with respect to the research, authorship and publication of this article.

Authors’ contributions

S.M. made substantial contributions to the conception and design of the work, the acquisition, analysis and interpretation of data for the work, drafting and revising the manuscript and final approval for publishing. R.D.P. was responsible for the interpretation of data, drafting and revising the manuscript and final approval for publishing. R.P. contributed to the conception and design of the work, the acquisition, analysis and interpretation of data, drafting and revising of the manuscript and final approval for publishing. M.D.M.G. was involved in the conception and design of the work, the acquisition and interpretation of data, drafting and revising of the manuscript and final approval for publishing.

Funding

This research received no specific grant from any funding agency in the public, commercial or non-profit sectors.

Data availability statement

The data that support the findings of this study are available from the corresponding author, S.M., upon reasonable request.

Disclaimer

The views and opinions expressed in this article are the authors’ own and not an official position of the institution or funder.

References

  1. Koo KP, Traverse WW. Do preoperative indicators predict the presence of common bile duct stones during laparoscopic cholecystectomy? Am J Surg. 1996;171(5):495–499. https://doi.org/10.1016/S0002-9610(97)89611-0
  2. McCune WS, Shorb PE, Moscovitz H. Endoscopic cannulation of the ampulla of vater: A preliminary report. Ann Surg. 1968;167(5):752. https://doi.org/10.1097/00000658-196805000-00013
  3. Freeman ML. Adverse outcomes of ERCP. Gastrointest Endosc. 2002;56(6):147–168. https://doi.org/10.1067/mge.2002.129028
  4. Lal D, Lane M, Wong P. Complications of endoscopic retrograde cholangiopancreatography. New Zeal Med J [serial online]. 2003;116(1177):U496.
  5. Norton SA, Alderson D. Prospective comparison of endoscopic ultrasonography and endoscopic retrograde cholangiopancreatography in the detection of bile duct stones. BJS. 1997;84(10):1366–1369. https://doi.org/10.1002/bjs.1800841009
  6. Heller SL, Lee VS. MR imaging of the gallbladder and biliary system. Magn Reson Imaging Clin N Am. 2005;13(2):295–311. https://doi.org/10.1016/j.mric.2005.03.003
  7. Kats J, Kraai M, Dijkstra AJ, et al. Magnetic resonance cholangiopancreatography as a diagnostic tool for common bile duct stones: A comparison with ERCP and clinical follow-up. Dig Surg. 2003;20(1):32–37. https://doi.org/10.1159/000068863
  8. Parashari UC, Khanduri S, Bhadury S, Upadhyay D, Kishore K. Diagnostic role of magnetic resonance cholangiopancreatography in evaluation of obstructive biliopathies and correlating it with final diagnosis and clinical profile of patients. J Nat Sci Biol Med. 2015;6(1):131–138. https://doi.org/10.4103/0976-9668.149110
  9. Hjartarson JH, Hannesson P, Sverrisson I, Blöndal S, Ívarsson B, Björnsson ES. The value of magnetic resonance cholangiopancreatography for the exclusion of choledocholithiasis. Scand J Gastroenterol. 2016;51(10):1249–1256. https://doi.org/10.1080/00365521.2016.1182584
  10. Boraschi P, Neri E, Braccini G, et al. Cholodocholithiasis: Diagnostic accuracy of MR cholangiopancreatography. Three-year experience. Magn Reson Imaging. 1999;17(9):1245–1253. https://doi.org/10.1016/S0730-725X(99)00075-2
  11. Adamek HE, Albert J, Weitz M, Breer H, Schilling D, Riemann JF. A prospective evaluation of magnetic resonance cholangiopancreatography in patients with suspected bile duct obstruction. Gut. 1998;43(5):680–683. https://doi.org/10.1136/gut.43.5.680
  12. Wallner BK, Schumacher KA, Weidenmaier W, Friedrich JM. Dilated biliary tract: Evaluation with MR cholangiography with a T2-weighted contrast-enhanced fast sequence. Radiology. 1991;181(3):805–808. https://doi.org/10.1148/radiology.181.3.1947101
  13. Ringe KI, Hartung D, von Falck C, Wacker F, Raatschen H-J. 3D-MRCP for evaluation of intra- and extrahepatic bile ducts: Comparison of different acquisition and reconstruction planes. BMC Med Imaging. 2014;14:16. https://doi.org/10.1186/1471-2342-14-16
  14. Ohgi K, Satoh K, Tanaka S, et al. Elimination of artifacts in MRCP: Technical consideration. Nihon Rinsho. 1998;56(11):2854–2858.
  15. Gray H. Anatomy of the human body. 20th ed. In: Warren H. Lewis, editor. Chapter XI, 2j. The pancreas. Philadelphia, PA: Lea & Febiger, 1918; pp. 1200–1205.
  16. Hirohashi S, Hirohashi R, Uchida H, et al. MR cholangiopancreatography and MR urography: Improved enhancement with a negative oral contrast agent. Radiology. 1997;203(1):281–285. https://doi.org/10.1148/radiology.203.1.9122408
  17. Rijcken THP, Davis MA, Ros PP. Intraluminal contrast agents for MR imaging of the abdomen and pelvis. J Magn Reson Imaging. 1994;4(3):291–300. https://doi.org/10.1002/jmri.1880040312
  18. Chan JHM, Tsui EYK, Yuen MK, et al. Gadopentetate dimeglumine as an oral negative gastrointestinal contrast agent for MRCP. Abdom Imaging. 2000;25(4):405–408. https://doi.org/10.1007/s002610000018
  19. Petersein J, Reisinger W, Mutze S, Hamm B. Value of negative oral contrast media in MR cholangiopancreatography. RoFo Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nukl. 2000;172(1):55–60. https://doi.org/10.1055/s-2000-11100
  20. Frisch A, Walter TC, Hamm B, Denecke T. Efficacy of oral contrast agents for upper gastrointestinal signal suppression in MRCP: A systematic review of the literature. Acta Radiol Open. 2017;6(9):205846011772731. https://doi.org/10.1177/2058460117727315
  21. Giovagnoni A, Fabbri A, Maccioni F. Oral contrast agents in MRI of the gastrointestinal tract. Abdom Imaging. 2002;27(4):367–375. https://doi.org/10.1007/s00261-001-0117-5
  22. Riordan RD, Khonsari M, Jeffries J, Maskell GF, Cook PG. Pineapple juice as a negative oral contrast agent in magnetic resonance cholangiopancreatography: A preliminary evaluation. Br J Radiol. 2004;77(924):991–999. https://doi.org/10.1259/bjr/36674326
  23. Arrive L, Coudray C, Azizi L, et al. Pineapple juice as a negative oral contrast agent in magnetic resonance cholangiopancreatography. J Radiol. 2016;88(11 Pt 1):1689–1694. https://doi.org/10.1016/S0221-0363(07)74047-7
  24. Coppens E, Metens T, Winant C, Matos C. Pineapple juice labeled with gadolinium: A convenient oral contrast for magnetic resonance cholangiopancreatography. Eur Radiol. 2005;15(10):2122–2129. https://doi.org/10.1007/s00330-005-2835-5
  25. Wenker M, Vockelmann C, Schymura-Zahn A, Coesfeld DE. MRCP-alternatives to oral contrast agents containing iron oxide. ECR [serial online]. 2015 [cited 2015 Mar 04]. Available from: https://doi.org/10.1594/ecr2015/C-1913
  26. Duarte JA, Furtado APA, Marroni CA. Use of pineapple juice with gadopentetate dimeglumine as a negative oral contrast for magnetic resonance cholangiopancreatography: A multicentric study. Abdom Imaging. 2012;37(3):447–456. https://doi.org/10.1007/s00261-011-9761-6
  27. Ibrahim MA, Dublin AB. Magnetic resonance imaging (MRI) gadolinium. In: StatPearls. 2019 [cited 2020 Mar 09]. Available from: https://www.statpearls.com/
  28. Papanikolaou N, Karantanas A, Maris T, Gourtsoyiannis N. MR cholangiopancreatography before and after oral blueberry juice administration. J Comput Assist Tomogr. 2000;24(2):229–234. https://doi.org/10.1097/00004728-200003000-00008
  29. Hiraishi K, Narabayashi I, Fujita O, et al. Blueberry juice: Preliminary evaluation as an oral contrast agent in gastrointestinal MR imaging. Radiology. 1995;194(1):119–223. https://doi.org/10.1148/radiology.194.1.7997537
  30. Govindarajan A, Lakshmanan PM, Sarawagi R, Prabhakaran V. Evaluation of date syrup as an oral negative contrast agent for MRCP. AJR Am J Roentgenol. 2014;203(5):1001–1005. https://doi.org/10.2214/AJR.13.12299


Crossref Citations

No related citations found.